TEL:
+8618053657258

Carbonized composite tube heat exchanger is used more and more widely

Date:2022-11-29 16:36:37 Views:771
  New carbonized composite tube heat exchanger manual
Performance characteristics:
1、small size, light weight, compact structure, the use of carbonized composite tube as a heat exchanger material, high heat transfer efficiency, no hot and cold impact burst porcelain phenomenon, heat exchange through the reverse flow of hot air and cooling water.
2、The tube plate is made of PTFE, PFA, and F46, which is durable and will not be a problem for 10 years, and can be partially replaced if parts are damaged, which will not cause the whole machine to be scrapped or shut down, greatly extending the service life of the whole machine.
3、Carbonized composite tube condenser can withstand pressure -1MPA-1.5MPA, temperature -90°-180°, and not easy to scale, compared with glass-lined sheet condenser, glass, PTFE heat exchange efficiency can be increased by 2-3.5 times.
4、carbonized composite tube condenser that pressure, thermal conductivity and good, and corrosion resistance, the use of high strength and now a large number of replace graphite heat exchanger, stainless steel and other precious metal heat exchanger.
Instructions for use:
1、the condenser head is glass-lined, fluorine-lined, glass, stainless steel and other materials, assembly in accordance with the drawings and relevant requirements; assembly or installation is strictly prohibited sharp, hard material impact, friction glass surface and fluorine-lined surface.
2、lifting should be careful, lightly, to prevent collision damage to the internal carbonized composite pipe equipment.
3、During transportation and use of the equipment, violent vibration is strictly prohibited to prevent the carbonized composite tube from being damaged.
4、 carbonized composite condenser is not afraid of hot and cold shock, but must be used within the specified temperature and pressure range, pay attention to the medium solidification temperature, causing the internal medium solidification of the tube body, resulting in carbonized composite tube internal service expansion cracking.
5、 carbonized composite condenser in the process of use, the material and cooling water inlet valve should be kept open slowly and evenly to avoid generating a violent shock vibration to the interior of the equipment instantly.
6、It is recommended to use clean cooling water to avoid sludge blockage in the condensing channel.
7、The material inside the container should not have crystallization inside the container to avoid blocking the carbonized composite pipeline and reducing the heat exchange effect.
8、If local blockage occurs during use, it cannot be cleaned with hard rods and cleaned with acid using water.
9、In the process of use, the outer surface of the equipment and the screws should be anti-corrosion treatment to prevent the screws from rusting.
Cautions:
1、Using pressure: Tube process: ultimate vacuum <P<0.4MPa; Shell process: 0<P<0.6MPa.(If there are special requirements, please inform the company before ordering).
2、Although the carbonized composite tube heat exchanger has high pressure resistance, but it is not a pressure vessel, so please pay attention when using it to prevent the phenomenon of carbonized composite tube rupture.
3、the company's new carbonized composite tube heat exchanger factory has all been strictly tested, please do not disassemble the customer, otherwise the problems caused by the company is not responsible. If there is a problem, please notify the company, our company will arrange for professional and technical personnel to visit your home.